Model NO.: PTA, QTA Series
Mixture: 30% Diesel ,70% Natural Gas
Warranty: 1 Year or 1200 Working Hours
After-Sales Service Provided: Engineers Available to Service Machinery Overseas
Gas Train: Ball Valve, Gas Filter, Gas Regulator, Gas Control
Nox Emission: 100% Load Below 500mg/Nm3
Trademark: Googol
Transport Package: Standard
Specification: ISO3046, ISO8528
Origin: Guangdong, China
HS Code: 8502120000
Model NO.: PTA, QTA Series
Mixture: 30% Diesel ,70% Natural Gas
Warranty: 1 Year or 1200 Working Hours
After-Sales Service Provided: Engineers Available to Service Machinery Overseas
Gas Train: Ball Valve, Gas Filter, Gas Regulator, Gas Control
Nox Emission: 100% Load Below 500mg/Nm3
Trademark: Googol
Transport Package: Standard
Specification: ISO3046, ISO8528
Origin: Guangdong, China
HS Code: 8502120000
60Hz Googol Natural Gas Diesel Fuel Dual Engine for Generator 260kW-1560kWNote:
1. All engine parameters are in accordance with ISO3046, ISO8528.
2. All engine parameters are based on 25° C / 100kPa environment condition.
3. Application for Power Generation, Marine, Pump Driving, CHP power plant.
Applied gas:
Natural Gas, Biogas, City Sewage Gas, Landfill gas, Oil gas, farm biogas, Coal mine gas, etc
Acceptable fuel gas pressure: 5~12kPa
CH4 content: For natural gas≥ 85% CH4, content: For biogas≥ 40%
Gas heat value≥ 5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency.
Gas doesn't include free water or free materials (the size of impurities should be less than 5μ M. )
H2S content≤ 200mg/Nm³
NH3 content≤ 20mg/Nm³
Impurities content≤ 30mg/Nm³ ; Size≤ 5μ M
Water content≤ 40g/Nm³ , no free water.
Acceptable working conditions:
Ambient temperature: -10° C~+40° C
(antifreeze or preheater needed for below 0° C)
Relative humidity: <90%(20° C)
Altitude: ≤ 1000m
Normal working conditions:
Genset can run at rated power on the conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 20° C, Relative Humidity: 30%.
Standard scope of supply:
1, Gas Engine
2, AC Generator
3, Common Frame
4, Control Panel
5, Ignition System: Ignition Controller, Ignition Coils, Output harness, Pickup magnetic, Trigger disc, PolyMot high tension lead, Spark Plug
6, Detonation Controller System: DetCon20 control unit, Detonation sensor, Cable & knock sensor
7, Electronic Speed Controller System: Integrated Throttle body, Vari-Step stepper motor card, Harness VariFuel, Electronic speed controller - ECON-4, pickup magnetic
8, Gas Mixer System: VariFuel air/fuel ratio mixer, VF Flange, VariStep stepper motor card, Harness VariFuel, VariFuel2 flow body
9. Emission Control System: EmCon5 control unit, EmCon5 sensor harness, knock sensor
10, Valve: Gas Pressure Valve, Solenoid Valve, Cutoff Valve
11, Exhaust Bellows & Muffler
12, Radiator for optional
Warranty:
All equipment is guaranteed for a period of 1000 hours running or 18 months from the date when the generator set has been delivered from the factory.
Googol Series Dual Fuel Generator, 1800rpm/1200rpm, 60Hz |  |  |  |  |  |  |  |  |  |  |
Genset Model |  | HDGM450/6 | HDGM500/6 | HDGM550/6 | HDGM688/6 | HDGM825/6 | HDGM1000/6 | HDGM1375/6 | HDGM1876/6 | HDGM2500/6 |
Engine Model |  | PTA780BG2 | PTAA780BG2 | PTAA890BG2 | PTAA1120BG2 | PTAA1340BG2 | QTA2160BSG2 | QTA3240BSG2 | QTA4320BSG2 | QTA5400BSG2 |
Rating Speed | rpm | 1800 | 1800 | 1800 | 1800 | 1800 | 1200 | 1200 | 1200 | 1200 |
Frequency | Hz | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 |
Generator Continuous Output (COP) | kW | 260 | 280 | 360 | 400 | 540 | 640 | 900 | 1200 | 1560 |
Generator Prime Output (PRP) | kW | 320 | 360 | 400 | 500 | 600 | 720 | 1000 | 1365 | 1800 |
Generator Standby Output (LTP) | kW | 360 | 400 | 440 | 550 | 660 | 800 | 1100 | 1500 | 2000 |
Power Factor |  | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 |
Gas Engine Parameter |  |  |  |  |  |  |  |  |  |  |
Engine Continuous Output  (COP) | kW | 297 | 316 | 407 | 456 | 616 | 722 | 964 | 1244 | 1617 |
Engine Prime Output  (PRP) | kW | 361 | 402 | 445 | 562 | 680 | 804 | 1098 | 1485 | 1865 |
Engine Standby Output  (LTP) | kW | 404 | 445 | 503 | 615 | 744 | 880 | 1203 | 1624 | 2073 |
Configuration |  | 6 In line | 6 In line | 8 Vee | 10 Vee | 12 Vee | 8 Vee | 12 Vee | 16 Vee | 20 Vee |
Displacement | l | 12.8 | 12.8 | 14.6 | 18.3 | 21.9 | 35.4 | 53.1 | 70.8 | 88.5 |
Bore | mm | 128 | 128 | 128 | 128 | 128 | 170 | 170 | 170 | 170 |
Stroke | mm | 166 | 166 | 142 | 142 | 142 | 195 | 195 | 195 | 195 |
Compression Ratio |  | 15.5:1 | 15.5:1 | 14.6:1 | 14.6:1 | 14.6:1 | 13.5:1 | 13.5:1 | 13.5:1 | 13.5:1 |
Piston Speed | m/s | 9.96 | 9.96 | 8.52 | 8.52 | 8.52 | 7.8 | 7.8 | 7.8 | 7.8 |
Number of Flywheel Teeth |  | 160 | 160 | 160 | 160 | 160 | 218 | 218 | 218 | 218 |
Flywheel House Size |  | SAE1-14 | SAE1-14 | SAE1-14 | SAE1-14 | SAE1-14 | SAE00-18 | SAE00-21 | SAE00-21 | SAE00-21 |
System Parameter |  |  |  |  |  |  |  |  |  |  |
Oil Capacity | l | 40 | 40 | 32 | 40 | 45 | 160 | 180 | 240 | 300 |
Max. Allowed Oil Temperature | °C | 110 | 110 | 110 | 110 | 110 | 110 | 110 | 110 | 110 |
Oil Pressure Warning | kPa | 200 | 200 | 200 | 200 | 200 | 300 | 300 | 300 | 300 |
Oil Pressure Shutdown | kPa | 160 | 160 | 160 | 160 | 160 | 200 | 200 | 200 | 200 |
Coolant Capacity for Engine | l | 18 | 18 | 20 | 21 | 23 | 70 | 100 | 140 | 200 |
Max. Coolant Warning Temperature  | °C | 95 | 95 | 95 | 95 | 95 | 93 | 93 | 93 | 93 |
Max. Coolant Shutdown Temperature  | °C | 105 | 105 | 105 | 105 | 105 | 97 | 97 | 97 | 97 |
Flow of Coolant pump | m³/h | 23.6 | 23.6 | 30.5 | 30.5 | 36 | 38/36 | 38/36 | 64/60 | 64/60 |
Max. Exhaust Temperature | °C | 525 | 520 | 480 | 500 | 500 | 500 | 480 | 500 | 530 |
Exhaust Flow | m³/min | 44 | 48 | 60 | 67 | 81 | 196 | 297 | 428 | 504 |
Exhaust Flange Diameter | mm | 125 | 125 | 2*100 | 2*100 | 2*125 | 250 | 2*250 | 2*250 | 2*250 |
Charging Alternator Capacity | A | 35 | 35 | 35 | 35 | 35 | 55 | 55 | 55 | 55 |
Starting Voltage | V | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 |
Fuel & Gas Consumption (PRP) |  |  |  |  |  |  |  |  |  |  |
Fuel Consumption at 75% Load | l/h | 21 | 23 | 29 | 34 | 40 | 48 | 55 | 80 | 94 |
Gas Consumption at 75% Load | m³/h | 36 | 41 | 72 | 81 | 98 | 120 | 149 | 215 | 253 |
Fuel Consumption at 100% Load | l/h | 28 | 31 | 39 | 44 | 53 | 62 | 74 | 107 | 126 |
Gas Consumption at 100% Load | m³/h | 49 | 54 | 96 | 108 | 130 | 159 | 198 | 286 | 337 |
Generator Parameter |  |  |  |  |  |  |  |  |  |  |
Generator Model |  | ECO38-3LN/4 | ECO40-1S/4 | ECO40-2S/4 | ECO40-1L/4 | ECO40-2L/4 | MX-750-6 | MX-1000-6 | MX-1500-6 | MX-1800-6 |
Generator Prime Output | kW | 336 | 384 | 432 | 528 | 653 | 750 | 1000 | 1500 | 1800 |
Generator Efficiency @ 0.8PF |  | 94.3% | 95.0% | 94.7% | 95.2% | 95.8% | 95.3% | 95.4% | 95.5% | 96.3% |
Genset Dimension |  |  |  |  |  |  |  |  |  |  |
Length | mm | 3100 | 3100 | 3300 | 3500 | 3600 | 4600 | 5200 | 5600 | * 5600 |
Width | mm | 1300 | 1300 | 1500 | 1500 | 1500 | 2190 | 2190 | 2190 | * 1800 |
Height | mm | 1700 | 1700 | 2000 | 2000 | 2000 | 2300 | 2580 | 2800 | * 2400 |
Genset Weight | kg | 2500 | 2500 | 3500 | 3900 | 4300 | 7650 | 10500 | 13500 | 16500 |
60Hz Googol Natural Gas Diesel Fuel Dual Engine for Generator 260kW-1560kW
Note:
1. All engine parameters are in accordance with ISO3046, ISO8528.
2. All engine parameters are based on 25° C / 100kPa environment condition.
3. Application for Power Generation, Marine, Pump Driving, CHP power plant.
Applied gas:
Natural Gas, Biogas, City Sewage Gas, Landfill gas, Oil gas, farm biogas, Coal mine gas, etc
Acceptable fuel gas pressure: 5~12kPa
CH4 content: For natural gas≥ 85% CH4, content: For biogas≥ 40%
Gas heat value≥ 5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency.
Gas doesn't include free water or free materials (the size of impurities should be less than 5μ M. )
H2S content≤ 200mg/Nm³
NH3 content≤ 20mg/Nm³
Impurities content≤ 30mg/Nm³ ; Size≤ 5μ M
Water content≤ 40g/Nm³ , no free water.
Acceptable working conditions:
Ambient temperature: -10° C~+40° C
(antifreeze or preheater needed for below 0° C)
Relative humidity: <90%(20° C)
Altitude: ≤ 1000m
Normal working conditions:
Genset can run at rated power on the conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 20° C, Relative Humidity: 30%.
Standard scope of supply:
1, Gas Engine
2, AC Generator
3, Common Frame
4, Control Panel
5, Ignition System: Ignition Controller, Ignition Coils, Output harness, Pickup magnetic, Trigger disc, PolyMot high tension lead, Spark Plug
6, Detonation Controller System: DetCon20 control unit, Detonation sensor, Cable & knock sensor
7, Electronic Speed Controller System: Integrated Throttle body, Vari-Step stepper motor card, Harness VariFuel, Electronic speed controller - ECON-4, pickup magnetic
8, Gas Mixer System: VariFuel air/fuel ratio mixer, VF Flange, VariStep stepper motor card, Harness VariFuel, VariFuel2 flow body
9. Emission Control System: EmCon5 control unit, EmCon5 sensor harness, knock sensor
10, Valve: Gas Pressure Valve, Solenoid Valve, Cutoff Valve
11, Exhaust Bellows & Muffler
12, Radiator for optional
Warranty:
All equipment is guaranteed for a period of 1000 hours running or 18 months from the date when the generator set has been delivered from the factory.
Googol Series Dual Fuel Generator, 1800rpm/1200rpm, 60Hz |  |  |  |  |  |  |  |  |  |  |
Genset Model |  | HDGM450/6 | HDGM500/6 | HDGM550/6 | HDGM688/6 | HDGM825/6 | HDGM1000/6 | HDGM1375/6 | HDGM1876/6 | HDGM2500/6 |
Engine Model |  | PTA780BG2 | PTAA780BG2 | PTAA890BG2 | PTAA1120BG2 | PTAA1340BG2 | QTA2160BSG2 | QTA3240BSG2 | QTA4320BSG2 | QTA5400BSG2 |
Rating Speed | rpm | 1800 | 1800 | 1800 | 1800 | 1800 | 1200 | 1200 | 1200 | 1200 |
Frequency | Hz | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 |
Generator Continuous Output (COP) | kW | 260 | 280 | 360 | 400 | 540 | 640 | 900 | 1200 | 1560 |
Generator Prime Output (PRP) | kW | 320 | 360 | 400 | 500 | 600 | 720 | 1000 | 1365 | 1800 |
Generator Standby Output (LTP) | kW | 360 | 400 | 440 | 550 | 660 | 800 | 1100 | 1500 | 2000 |
Power Factor |  | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 |
Gas Engine Parameter |  |  |  |  |  |  |  |  |  |  |
Engine Continuous Output  (COP) | kW | 297 | 316 | 407 | 456 | 616 | 722 | 964 | 1244 | 1617 |
Engine Prime Output  (PRP) | kW | 361 | 402 | 445 | 562 | 680 | 804 | 1098 | 1485 | 1865 |
Engine Standby Output  (LTP) | kW | 404 | 445 | 503 | 615 | 744 | 880 | 1203 | 1624 | 2073 |
Configuration |  | 6 In line | 6 In line | 8 Vee | 10 Vee | 12 Vee | 8 Vee | 12 Vee | 16 Vee | 20 Vee |
Displacement | l | 12.8 | 12.8 | 14.6 | 18.3 | 21.9 | 35.4 | 53.1 | 70.8 | 88.5 |
Bore | mm | 128 | 128 | 128 | 128 | 128 | 170 | 170 | 170 | 170 |
Stroke | mm | 166 | 166 | 142 | 142 | 142 | 195 | 195 | 195 | 195 |
Compression Ratio |  | 15.5:1 | 15.5:1 | 14.6:1 | 14.6:1 | 14.6:1 | 13.5:1 | 13.5:1 | 13.5:1 | 13.5:1 |
Piston Speed | m/s | 9.96 | 9.96 | 8.52 | 8.52 | 8.52 | 7.8 | 7.8 | 7.8 | 7.8 |
Number of Flywheel Teeth |  | 160 | 160 | 160 | 160 | 160 | 218 | 218 | 218 | 218 |
Flywheel House Size |  | SAE1-14 | SAE1-14 | SAE1-14 | SAE1-14 | SAE1-14 | SAE00-18 | SAE00-21 | SAE00-21 | SAE00-21 |
System Parameter |  |  |  |  |  |  |  |  |  |  |
Oil Capacity | l | 40 | 40 | 32 | 40 | 45 | 160 | 180 | 240 | 300 |
Max. Allowed Oil Temperature | °C | 110 | 110 | 110 | 110 | 110 | 110 | 110 | 110 | 110 |
Oil Pressure Warning | kPa | 200 | 200 | 200 | 200 | 200 | 300 | 300 | 300 | 300 |
Oil Pressure Shutdown | kPa | 160 | 160 | 160 | 160 | 160 | 200 | 200 | 200 | 200 |
Coolant Capacity for Engine | l | 18 | 18 | 20 | 21 | 23 | 70 | 100 | 140 | 200 |
Max. Coolant Warning Temperature  | °C | 95 | 95 | 95 | 95 | 95 | 93 | 93 | 93 | 93 |
Max. Coolant Shutdown Temperature  | °C | 105 | 105 | 105 | 105 | 105 | 97 | 97 | 97 | 97 |
Flow of Coolant pump | m³/h | 23.6 | 23.6 | 30.5 | 30.5 | 36 | 38/36 | 38/36 | 64/60 | 64/60 |
Max. Exhaust Temperature | °C | 525 | 520 | 480 | 500 | 500 | 500 | 480 | 500 | 530 |
Exhaust Flow | m³/min | 44 | 48 | 60 | 67 | 81 | 196 | 297 | 428 | 504 |
Exhaust Flange Diameter | mm | 125 | 125 | 2*100 | 2*100 | 2*125 | 250 | 2*250 | 2*250 | 2*250 |
Charging Alternator Capacity | A | 35 | 35 | 35 | 35 | 35 | 55 | 55 | 55 | 55 |
Starting Voltage | V | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 |
Fuel & Gas Consumption (PRP) |  |  |  |  |  |  |  |  |  |  |
Fuel Consumption at 75% Load | l/h | 21 | 23 | 29 | 34 | 40 | 48 | 55 | 80 | 94 |
Gas Consumption at 75% Load | m³/h | 36 | 41 | 72 | 81 | 98 | 120 | 149 | 215 | 253 |
Fuel Consumption at 100% Load | l/h | 28 | 31 | 39 | 44 | 53 | 62 | 74 | 107 | 126 |
Gas Consumption at 100% Load | m³/h | 49 | 54 | 96 | 108 | 130 | 159 | 198 | 286 | 337 |
Generator Parameter |  |  |  |  |  |  |  |  |  |  |
Generator Model |  | ECO38-3LN/4 | ECO40-1S/4 | ECO40-2S/4 | ECO40-1L/4 | ECO40-2L/4 | MX-750-6 | MX-1000-6 | MX-1500-6 | MX-1800-6 |
Generator Prime Output | kW | 336 | 384 | 432 | 528 | 653 | 750 | 1000 | 1500 | 1800 |
Generator Efficiency @ 0.8PF |  | 94.3% | 95.0% | 94.7% | 95.2% | 95.8% | 95.3% | 95.4% | 95.5% | 96.3% |
Genset Dimension |  |  |  |  |  |  |  |  |  |  |
Length | mm | 3100 | 3100 | 3300 | 3500 | 3600 | 4600 | 5200 | 5600 | * 5600 |
Width | mm | 1300 | 1300 | 1500 | 1500 | 1500 | 2190 | 2190 | 2190 | * 1800 |
Height | mm | 1700 | 1700 | 2000 | 2000 | 2000 | 2300 | 2580 | 2800 | * 2400 |
Genset Weight | kg | 2500 | 2500 | 3500 | 3900 | 4300 | 7650 | 10500 | 13500 | 16500 |
DC Motor