60Hz Googol Natural Gas Diesel Fuel Dual Engine for Generator 320kw-1800kw

Model NO.: PTA, QTA Series
Mixture: 30% Diesel ,70% Natural Gas
Warranty: 1 Year or 1200 Working Hours
After-Sales Service Provided: Engineers Available to Service Machinery Overseas
Gas Train: Ball Valve, Gas Filter, Gas Regulator, Gas Control
Nox Emission: 100% Load Below 500mg/Nm3
Trademark: Googol
Transport Package: Standard
Specification: ISO3046, ISO8528
Origin: Guangdong, China
HS Code: 8502120000
Model NO.: PTA, QTA Series
Mixture: 30% Diesel ,70% Natural Gas
Warranty: 1 Year or 1200 Working Hours
After-Sales Service Provided: Engineers Available to Service Machinery Overseas
Gas Train: Ball Valve, Gas Filter, Gas Regulator, Gas Control
Nox Emission: 100% Load Below 500mg/Nm3
Trademark: Googol
Transport Package: Standard
Specification: ISO3046, ISO8528
Origin: Guangdong, China
HS Code: 8502120000
60Hz Googol Natural Gas Diesel Fuel Dual Engine for Generator 260kW-1560kW


Note:
1. All engine parameters are in accordance with ISO3046, ISO8528.
2. All engine parameters are based on 25° C / 100kPa environment condition.
3. Application for Power Generation, Marine, Pump Driving, CHP power plant.


Applied gas:

Natural Gas, Biogas, City Sewage Gas, Landfill gas, Oil gas, farm biogas, Coal mine gas, etc

Acceptable fuel gas pressure: 5~12kPa

CH4 content: For natural gas≥ 85% CH4, content: For biogas≥ 40%

Gas heat value≥ 5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency.

Gas doesn't include free water or free materials (the size of impurities should be less than 5μ M. )

H2S content≤ 200mg/Nm³

NH3 content≤ 20mg/Nm³

Impurities content≤ 30mg/Nm³ ; Size≤ 5μ M

Water content≤ 40g/Nm³ , no free water.


Acceptable working conditions:

Ambient temperature: -10° C~+40° C

(antifreeze or preheater needed for below 0° C)

Relative humidity: <90%(20° C)

Altitude: ≤ 1000m

Normal working conditions:

Genset can run at rated power on the conditions:

Atmospheric Pressure: 100kPa, Ambient Temp: 20° C, Relative Humidity: 30%.

Standard scope of supply:
1, Gas Engine

2, AC Generator

3, Common Frame

4, Control Panel

5, Ignition System: Ignition Controller, Ignition Coils, Output harness, Pickup magnetic, Trigger disc, PolyMot high tension lead, Spark Plug

6, Detonation Controller System: DetCon20 control unit, Detonation sensor, Cable & knock sensor

7, Electronic Speed Controller System: Integrated Throttle body, Vari-Step stepper motor card, Harness VariFuel, Electronic speed controller - ECON-4, pickup magnetic

8, Gas Mixer System: VariFuel air/fuel ratio mixer, VF Flange, VariStep stepper motor card, Harness VariFuel, VariFuel2 flow body

9. Emission Control System: EmCon5 control unit, EmCon5 sensor harness, knock sensor

10, Valve: Gas Pressure Valve, Solenoid Valve, Cutoff Valve

11, Exhaust Bellows & Muffler

12, Radiator for optional

Warranty:
All equipment is guaranteed for a period of 1000 hours running or 18 months from the date when the generator set has been delivered from the factory.
Googol Series Dual Fuel Generator, 1800rpm/1200rpm, 60Hz                    
Genset Model   HDGM450/6 HDGM500/6 HDGM550/6 HDGM688/6 HDGM825/6 HDGM1000/6 HDGM1375/6 HDGM1876/6 HDGM2500/6
Engine Model   PTA780BG2 PTAA780BG2 PTAA890BG2 PTAA1120BG2 PTAA1340BG2 QTA2160BSG2 QTA3240BSG2 QTA4320BSG2 QTA5400BSG2
Rating Speed  rpm 1800 1800 1800 1800 1800 1200 1200 1200 1200
Frequency  Hz 60 60 60 60 60 60 60 60 60
Generator Continuous Output (COP) kW 260  280  360  400  540  640  900  1200  1560 
Generator Prime Output (PRP) kW 320  360  400  500  600  720  1000  1365  1800 
Generator Standby Output (LTP) kW 360  400  440  550  660  800  1100  1500  2000 
Power Factor   0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Gas Engine Parameter                    
Engine Continuous Output  (COP) kW 297  316  407  456  616  722 964  1244  1617 
Engine Prime Output  (PRP) kW 361  402  445  562  680  804 1098  1485  1865 
Engine Standby Output  (LTP) kW 404  445  503  615  744  880 1203  1624  2073 
Configuration   6 In line 6 In line 8 Vee 10 Vee 12 Vee 8 Vee 12 Vee 16 Vee 20 Vee
Displacement  l 12.8 12.8 14.6 18.3 21.9 35.4 53.1 70.8 88.5
Bore  mm 128 128 128 128 128 170 170 170 170
Stroke  mm 166 166 142 142 142 195 195 195 195
Compression Ratio   15.5:1 15.5:1 14.6:1 14.6:1 14.6:1 13.5:1 13.5:1 13.5:1 13.5:1
Piston Speed  m/s 9.96 9.96 8.52 8.52 8.52 7.8 7.8 7.8 7.8
Number of Flywheel Teeth    160  160  160  160  160  218  218  218  218 
Flywheel House Size   SAE1-14 SAE1-14 SAE1-14 SAE1-14 SAE1-14 SAE00-18 SAE00-21 SAE00-21 SAE00-21
System Parameter                    
Oil Capacity  l 40 40 32 40 45 160 180 240 300
Max. Allowed Oil Temperature  °C 110 110 110 110 110 110 110 110 110
Oil Pressure Warning  kPa 200  200  200  200  200  300  300  300  300 
Oil Pressure Shutdown  kPa 160  160  160  160  160  200  200  200  200 
Coolant Capacity for Engine  l 18 18 20 21 23 70 100 140 200
Max. Coolant Warning Temperature   °C 95 95 95 95 95 93 93 93 93
Max. Coolant Shutdown Temperature   °C 105 105 105 105 105 97 97 97 97
Flow of Coolant pump  m³/h 23.6 23.6 30.5 30.5 36 38/36 38/36 64/60 64/60
Max. Exhaust Temperature °C 525 520 480 500 500 500 480 500 530
Exhaust Flow m³/min 44 48 60 67 81 196 297 428 504
Exhaust Flange Diameter  mm 125 125 2*100 2*100 2*125 250 2*250 2*250 2*250
Charging Alternator Capacity  A 35 35 35 35 35 55 55 55 55
Starting Voltage  V 24 24 24 24 24 24 24 24 24
Fuel & Gas Consumption (PRP)                    
Fuel Consumption at 75% Load l/h 21 23 29  34  40  48  55  80  94 
Gas Consumption at 75% Load m³/h 36 41 72 81 98 120 149 215 253
Fuel Consumption at 100% Load l/h 28 31 39 44 53 62 74 107 126
Gas Consumption at 100% Load m³/h 49 54 96 108 130 159 198 286 337
Generator Parameter                    
Generator Model   ECO38-3LN/4 ECO40-1S/4 ECO40-2S/4 ECO40-1L/4 ECO40-2L/4 MX-750-6 MX-1000-6 MX-1500-6 MX-1800-6
Generator Prime Output kW 336 384 432 528 653 750 1000 1500 1800
Generator Efficiency @ 0.8PF   94.3% 95.0% 94.7% 95.2% 95.8% 95.3% 95.4% 95.5% 96.3%
Genset Dimension                    
Length  mm 3100 3100 3300 3500 3600 4600 5200 5600 * 5600
Width  mm 1300 1300 1500 1500 1500 2190 2190 2190 * 1800
Height  mm 1700 1700 2000 2000 2000 2300 2580 2800 * 2400
Genset Weight kg 2500 2500 3500 3900 4300 7650 10500 13500 16500


60Hz Googol Natural Gas Diesel Fuel Dual Engine for Generator 320kw-1800kw 60Hz Googol Natural Gas Diesel Fuel Dual Engine for Generator 260kW-1560kW


Note:
1. All engine parameters are in accordance with ISO3046, ISO8528.
2. All engine parameters are based on 25° C / 100kPa environment condition.
3. Application for Power Generation, Marine, Pump Driving, CHP power plant.


Applied gas:

Natural Gas, Biogas, City Sewage Gas, Landfill gas, Oil gas, farm biogas, Coal mine gas, etc

Acceptable fuel gas pressure: 5~12kPa

CH4 content: For natural gas≥ 85% CH4, content: For biogas≥ 40%

Gas heat value≥ 5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency.

Gas doesn't include free water or free materials (the size of impurities should be less than 5μ M. )

H2S content≤ 200mg/Nm³

NH3 content≤ 20mg/Nm³

Impurities content≤ 30mg/Nm³ ; Size≤ 5μ M

Water content≤ 40g/Nm³ , no free water.


Acceptable working conditions:

Ambient temperature: -10° C~+40° C

(antifreeze or preheater needed for below 0° C)

Relative humidity: <90%(20° C)

Altitude: ≤ 1000m

Normal working conditions:

Genset can run at rated power on the conditions:

Atmospheric Pressure: 100kPa, Ambient Temp: 20° C, Relative Humidity: 30%.

Standard scope of supply:
1, Gas Engine

2, AC Generator

3, Common Frame

4, Control Panel

5, Ignition System: Ignition Controller, Ignition Coils, Output harness, Pickup magnetic, Trigger disc, PolyMot high tension lead, Spark Plug

6, Detonation Controller System: DetCon20 control unit, Detonation sensor, Cable & knock sensor

7, Electronic Speed Controller System: Integrated Throttle body, Vari-Step stepper motor card, Harness VariFuel, Electronic speed controller - ECON-4, pickup magnetic

8, Gas Mixer System: VariFuel air/fuel ratio mixer, VF Flange, VariStep stepper motor card, Harness VariFuel, VariFuel2 flow body

9. Emission Control System: EmCon5 control unit, EmCon5 sensor harness, knock sensor

10, Valve: Gas Pressure Valve, Solenoid Valve, Cutoff Valve

11, Exhaust Bellows & Muffler

12, Radiator for optional

Warranty:
All equipment is guaranteed for a period of 1000 hours running or 18 months from the date when the generator set has been delivered from the factory.
Googol Series Dual Fuel Generator, 1800rpm/1200rpm, 60Hz                    
Genset Model   HDGM450/6 HDGM500/6 HDGM550/6 HDGM688/6 HDGM825/6 HDGM1000/6 HDGM1375/6 HDGM1876/6 HDGM2500/6
Engine Model   PTA780BG2 PTAA780BG2 PTAA890BG2 PTAA1120BG2 PTAA1340BG2 QTA2160BSG2 QTA3240BSG2 QTA4320BSG2 QTA5400BSG2
Rating Speed  rpm 1800 1800 1800 1800 1800 1200 1200 1200 1200
Frequency  Hz 60 60 60 60 60 60 60 60 60
Generator Continuous Output (COP) kW 260  280  360  400  540  640  900  1200  1560 
Generator Prime Output (PRP) kW 320  360  400  500  600  720  1000  1365  1800 
Generator Standby Output (LTP) kW 360  400  440  550  660  800  1100  1500  2000 
Power Factor   0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Gas Engine Parameter                    
Engine Continuous Output  (COP) kW 297  316  407  456  616  722 964  1244  1617 
Engine Prime Output  (PRP) kW 361  402  445  562  680  804 1098  1485  1865 
Engine Standby Output  (LTP) kW 404  445  503  615  744  880 1203  1624  2073 
Configuration   6 In line 6 In line 8 Vee 10 Vee 12 Vee 8 Vee 12 Vee 16 Vee 20 Vee
Displacement  l 12.8 12.8 14.6 18.3 21.9 35.4 53.1 70.8 88.5
Bore  mm 128 128 128 128 128 170 170 170 170
Stroke  mm 166 166 142 142 142 195 195 195 195
Compression Ratio   15.5:1 15.5:1 14.6:1 14.6:1 14.6:1 13.5:1 13.5:1 13.5:1 13.5:1
Piston Speed  m/s 9.96 9.96 8.52 8.52 8.52 7.8 7.8 7.8 7.8
Number of Flywheel Teeth    160  160  160  160  160  218  218  218  218 
Flywheel House Size   SAE1-14 SAE1-14 SAE1-14 SAE1-14 SAE1-14 SAE00-18 SAE00-21 SAE00-21 SAE00-21
System Parameter                    
Oil Capacity  l 40 40 32 40 45 160 180 240 300
Max. Allowed Oil Temperature  °C 110 110 110 110 110 110 110 110 110
Oil Pressure Warning  kPa 200  200  200  200  200  300  300  300  300 
Oil Pressure Shutdown  kPa 160  160  160  160  160  200  200  200  200 
Coolant Capacity for Engine  l 18 18 20 21 23 70 100 140 200
Max. Coolant Warning Temperature   °C 95 95 95 95 95 93 93 93 93
Max. Coolant Shutdown Temperature   °C 105 105 105 105 105 97 97 97 97
Flow of Coolant pump  m³/h 23.6 23.6 30.5 30.5 36 38/36 38/36 64/60 64/60
Max. Exhaust Temperature °C 525 520 480 500 500 500 480 500 530
Exhaust Flow m³/min 44 48 60 67 81 196 297 428 504
Exhaust Flange Diameter  mm 125 125 2*100 2*100 2*125 250 2*250 2*250 2*250
Charging Alternator Capacity  A 35 35 35 35 35 55 55 55 55
Starting Voltage  V 24 24 24 24 24 24 24 24 24
Fuel & Gas Consumption (PRP)                    
Fuel Consumption at 75% Load l/h 21 23 29  34  40  48  55  80  94 
Gas Consumption at 75% Load m³/h 36 41 72 81 98 120 149 215 253
Fuel Consumption at 100% Load l/h 28 31 39 44 53 62 74 107 126
Gas Consumption at 100% Load m³/h 49 54 96 108 130 159 198 286 337
Generator Parameter                    
Generator Model   ECO38-3LN/4 ECO40-1S/4 ECO40-2S/4 ECO40-1L/4 ECO40-2L/4 MX-750-6 MX-1000-6 MX-1500-6 MX-1800-6
Generator Prime Output kW 336 384 432 528 653 750 1000 1500 1800
Generator Efficiency @ 0.8PF   94.3% 95.0% 94.7% 95.2% 95.8% 95.3% 95.4% 95.5% 96.3%
Genset Dimension                    
Length  mm 3100 3100 3300 3500 3600 4600 5200 5600 * 5600
Width  mm 1300 1300 1500 1500 1500 2190 2190 2190 * 1800
Height  mm 1700 1700 2000 2000 2000 2300 2580 2800 * 2400
Genset Weight kg 2500 2500 3500 3900 4300 7650 10500 13500 16500


60Hz Googol Natural Gas Diesel Fuel Dual Engine for Generator 320kw-1800kw

EGR VALVE With Motor

DC Motor